SERIES 50 OPERATOR'S GUIDE OAT Organic Acid Technology. An inhibitor system based on organic acid inhibitors, instead of traditional North American inhibitor formulations. these coolants should be maintained according to the procedures discussed under Maintenance in this section. NOTICE: SCA Supplemental Coolant Additive. SCAs are used in a preventive maintenance program to prevent corrosion, cavitation, and the formation of deposits. Required specifications for water, ethylene glycol, propylene glycol, inhibitor packages and inhibitor concentration are included in this section.
To avoid possible engine damage from inadequate or overconcentrated coolant, this information should be read thoroughly before the coolant is replaced. Approved Coolants The approved and preferred coolants for Series 50 engines are listed in Table 21. Once installed, 1 Preferred Coolant 2 Water-only coolant systems offer no freeze protection and should not be used where ambient temperatures can fall to 32 °F (0 °C). Table 21 Initial Fill Coolant Options All information subject to change without notice. (Rev.
01/04) 97 DDC-SVC-MAN-0058 Copyright © 2004 DETROIT DIESEL CORPORATION Coolant Fill Option Product Ethylene Glycol & Water + Corrosion Inhibitors 1 DDC Power Cool Commercial Equivalent of DDC Power Cool Fully Formulated TMC RP-329 Type A Antifreeze & Water Propylene Glycol & Water + Corrosion Inhibitors 1 DDC Power Cool Plus Ethylene Glycol & Water + OAT Inhibitors DDC Power Cool Plus Water Only + Corrosion Inhibitors 2 Water + DDC Power Cool 3000 Water Only + OAT Inhibitors 2 Water + DDC Power Cool Plus 6000