DDEC IV SYSTEM In this situation the operator may elect to override the automatic stop engine sequence by pressing the Stop Engine Override switch every 15 to 20 seconds to prevent engine shutdown from occurring. Stop Engine Light The conditions that will cause the SEL to come on are: High coolant temperature Loss of coolant NOTE: For some applications, holding down the Stop Engine Override switch will not prevent the engine shutdown sequence. You must continue to reset the automatic shutdown system by pressing the Stop Engine Override switch at intervals of approximately 15 to 20 seconds.

High oil temperature Low oil pressure Auxiliary shutdown It is important to point out that whenever the CEL or the SEL comes on, the DDEC computer will determine where the problem is and will then store this information in its memory. It takes 30 seconds from the time the automatic shutdown sequence begins until engine shutdown. Therefore, the operator must press the override switch just prior to engine shutdown and continue to do so until the vehicle can be brought to a stop in a safe location. If the malfunction is intermittent, the lights will come on and go off as the computer senses the changing engine condition.

Diagnostic Data Reader The Diagnostic Data Reader (DDR) is a special diagnostic tool that can be plugged into the engine computer memory to extract information related to the cause of the problem. See Figure 7. Immediate Speed Reduction Option The immediate speed reduction option will bring engine rpm back to a predetermined speed, but will not shut down the engine. The engine should not be restarted after it has been shut down by the engine protection system, unless the problem has been located and corrected. 28 All information subject to change without notice. (Rev. 01/04) DDC-SVC-MAN-0058 Copyright © 2004 DETROIT DIESEL CORPORATION