MAN — MAN Series 50 Operator's Guide

MAINTENANCE Refer to SPECIFICATIONS for element part number listing. The valves mounted on the filter adaptor head must be opened after the element is replaced. Do not apply steam or solvent directly to the battery-charging alternator, starting motor, DDEC components, sensors or other electrical components, as damage to electrical equipment may result. NOTICE: Item 14 – Cranking Motor For cranking motor (starter) information, contact an authorized Delco Remy® or Bosch® service center, depending on manufacturer. Item 18 Radiator The exterior of the radiator core should be inspected every 30,000 miles (48,000 km), 12 months, or 300 hours (industrial applications) and cleaned, if necessary.

Item 15 Air System All the connections in the air system should be checked to make sure they are tight and leak free. Check all hoses and ducting for punctures, deterioration or other damage and replace, if necessary. EYE INJURY Item 16 – Exhaust System To avoid injury from flying debris when using compressed air, wear adequate eye protection (face shield or safety goggles) and do not exceed 276 kPa (40 psi) air pressure. Have the exhaust manifold retaining bolts and other connections checked for tightness. Have the exhaust pipe rain cap checked for proper operation, if so equipped.

Item 17 – Engine (Steam Clean) Use a quality grease solvent, such as mineral spirits, and dry with compressed air. Fuel oil, kerosene or gasoline should not be used. Steam clean the engine and engine compartment every 60,000 miles (96,000 km) or 2,000 hours, whichever comes first. It may be necessary to clean the radiator more frequently if the engine is being operated in extremely dusty or dirty areas. 78 All information subject to change without notice. (Rev. 01/04) DDC-SVC-MAN-0058 Copyright © 2004 DETROIT DIESEL CORPORATION