TRANSMISSION Ch 2 page 48 4. Remove wiring harness (1). 5. Loosen the cylindrical screw (2) of the differential lock solenoid valve. Figure 67 6. Remove the differential lock solenoid valve (1) with bracket (2). 7. Loosen the duct plate/valve block screw connection (3). 8. Remove the cylindrical screws (4) from the clamping plates. Figure 68 9. Remove valve block (1) and seal (2). 10. Remove screw plugs with O-ring (3). Figure 69 11. Remove all pressure controllers (1) with their clamping plates (2). Figure 70 SHOP MANUAL