Komatsu — WHEN REQUIRED

. MAINTENANCE MAINTENANCE PROCEDURE stopper, then remove it. 4 - 29 1. Stop the machine on level g 2. 3. Check that the cooling wat er temperature has gone down 4. enough to make it possible to touch the radiator cap surface by hand, then turn radiator cap stopper to release the pressu Following this, push radiator (2) slowly until it contacts the re. cap (2), turn it until it contacts the 5. Remove the undercover, the n set the container under drain mixture. valve (3) to catch the coolant Open drain valve (3) at the bo ttom of the radiator and drain the coolant. 6. After draining the coolant, clo se drain valve (3), and fill with city water.

When the radiator is fu ll, start the engine and run at low idling to raise the temperatu re to at least 90°C (194°F), then 0 minutes. ain valve (3) to drain the water. n the radiator with detergent. ow the instruction of detergent. e water filler up to the bottom of ant density, see the COOLANT for 5 minutes to remove the air continue to run for approx. 1 7. Stop the engine and open dr 8. After draining the water, clea For the cleaning method, foll 9. Close drain valve (3). Install the undercover. Add Supercoolant through th the filler port. For details of the Supercool 10. 11. DENSITY TABLE. Run the engine at low idling 12.

from the water, then run at h radiator cap (2) removed wh igh idling for 5 minutes. (Leave en doing this.)