Testing Fuel Lock-off Operation Fuel Trim Valve Inspection (FTV) z Start engine. z Visually inspect the Fuel trim valve (C) for abrasions or cracking. Replace as necessary. z Locate the electrical connector for the fuel lock (A). z Disconnect the electrical connector. z To ensure the valve is not leaking a blow-by test can be performed. 1. With the engine off, disconnect the electrical connector to the FTV. 2. Disconnect the vacuum line from the FTV to the pressure regulator/converter, at the converter’s tee connection. 3. Lightly blow through the vacuum line connected to the FTV. Air should not pass through the FTV when de-energized.
If air leaks past the FTV when de-energized replace the FTV. Inspect Air/Fuel Valve Mixer Assembly Refer to the LP mixer (G) section of the service manual for procedures. (G) LP mixer z The engine should run out of fuel and stop within a short period of time. z Turn the ignition key switch off and re-connect the fuel lock-off connector. (A) LP fuel lock-off (B) LP regulator/converter (C) Fuel Trim Valve NOTE The length of time the engine runs on trapped fuel vapor increases with any increase in distance between the fuel lock-off and the pressure regulator/converter.
Pressure Regulator/Converter Testing and Inspection A B C G z Visually inspect the pressure regulator/converter (B) housing for coolant leaks. Refer to the pressure regulator/converter section of the service manual if maintenance is required. NOTE For pressure testing and internal inspection of the pressure regulator/converter, refer to the pressure regulator/converter section of the service manual. G420E/G424E Tier LP Engine Maintenance Schedule 33