Table a. MI-04 Diagnostic Fault Codes (Flash Codes) G420E/G424E Tier LP Engine Advanced Diagnostics 57 DFC Probable Fault Action Corrective Action, First Check 65 Pedal2SensorInputLo APP2 sensor failure or shorted circuit MIN power Limit Check Acceleration Pedal connector z Cycle the pedal several times and check APP2 signal at SECM PIN 2 66 Pedal2SensorInputHi APP2 signal disconnected, open circuit or sensor malfunction (Expected faults when APP connector is unplugged CODES: 61 & 66) MIN power Limit Check Acceleration Pedal connector z Check APP2 signal at SECM PIN 2 67 Pedal2SensorRangeLo APP2 potentiometer malfunction.
Improper APP2 reading may be due to dirt or oxidation on the sensor traces. Stored Fault Code (MIL Only) Check Acceleration Pedal connector z Cycle the pedal several times and check APP2 signal at SECM PIN 2 68 Pedal2SensorRangeHi APP2 potentiometer malfunction. Improper APP2 reading may be due to dirt or oxidation on the sensor traces.
Stored Fault Code (MIL Only) Check Acceleration Pedal connector z Cycle the pedal several times and check APP2 signal at SECM PIN 2 69 Pedal1ToPedal2Difference Measured APP2 pedal position signal is different than APP1 signal MIN power Limit Check Acceleration Pedal connector z Cycle the pedal several times and check APP1 signal at SECM PIN 15 z Check APP2 signal at SECM PIN 2 71 AFRTrimValveOutput FTV modulation driver signal fault Stored Fault Code (MIL, Disable Adaptive learns) Check FTV for an open wire or FTV connector being disconnected FTV PIN A (SIGNAL) TO PIN B (PWR) Check FTV for an open coil by disconnecting the FTV connector and measuring the resistance (~26Ω +/- 2Ω) FTV PIN A (SIGNAL) TO PIN B (PWR)