daewoo — Daewoo SB4136E00 Service Manual for G420E/G424E Tier LP Engine Lift Trucks

CHAPTER 9 TEST AND ADJUSTMENTS WARNING N2001 Service Testing After overhaul or for simply checking the N2001 regulator/converter operation, the following tests can be performed (See Chapter 7 for removal/installation of the N2001). To check the secondary regulation (output) a simple vacuum hand pump can be used to simulate the vacuum signal transmitted from the air/fuel mixer when the engine is running. You will need the following hardware: Secondary Stage Test Hardware 1. Hand vacuum pump. 2. Regulator vapor outlet test fitting ѕ” NPT X ј” hose barb. 3. Union Tee ј” NPT with three ј” NPT X ј” hose barb. 4. Vacuum hose. 5. 0-3 in W.C. Magnehelic Gauge (inches of water column).

Secondary Stage (Break-Off) Test 1. Connect the vacuum pump, the Magnahelic gauge and the regulator vapor outlet to the Union Tee fitting (Figure R11). Make sure there is no leakage at any of the fittings. 2. Using the vacuum pump slowly apply enough vacuum to measure above -2 in WC on the gauge. This vacuum signal opens the secondary valve in the N2001 regulator/converter. 3. Release the vacuum pump lever and you will see the gauge needle start falling back toward zero. When the pressure drops just below the specified break-off pressure (-1.2 in WC) of the secondary spring, the needle should stop moving. 4. At this point the secondary valve should close.

If the secondary valve seat or the secondary diaphragm is leaking the gauge needle will continue to fall toward zero (proportional to the leak size). An excessively rich air/fuel mixture can be caused by a secondary valve seat leak, repair as necessary (See Chapter 7 for disassembly of the N2001). z LP gas is highly flammable. To prevent personal injury, keep fire and flammable materials away from the lift truck when work is done on the fuel system. z Gas vapor may reduce oxygen available for breathing, cause headache, nausea, dizziness and unconsciousness and lead to injury or death.

Always operate the forklift in a well ventilated area z Liquid propane may cause freezing of tissue or frostbite. Avoid direct contact with skin or tissue; always wear appropriate safety protection including gloves and safety glasses when working with liquid propane. CAUTION The regulator/converter and mixer are part of a certified system complying with EPA and CARB 2004 requirements. Only trained certified technicians should perform disassemble, service or replacement of the regulator/converter or mixer. G420E/G424E Tier LP Engine Test And Adjustments 78