Secondary Stage Test Connection Primary Stage Test Hardware 1. Hand vacuum pump. 2. Regulator Fuel Inlet test fitting (ј” NPT standard air coupling). 3. Test Gauge fitting (1/4” NPT X 1/4” Hose Barb). 4. Vacuum hose or vinyl tubing. 5. 0-60 in W.C. Magnehelic Gauge (inches of water column). Primary Stage Pressure Test 1. Remove the primary test port plug from the side of the regulator and install the ј” NPT hose barb fitting. 2. Connect a compressed air line (shop air ~100psi) to the liquid propane fuel inlet of the N2001 Regulator (Figure R12).
Magnahelic Gauge Vacuum Hand Pump Union Tee Vapor Outlet Test Fitting Figure R11 Test Port Fule Inlet Figure R12 G420E/G424E Tier LP Engine Test And Adjustments 79