Starting Systems/Bench Test CTM5 (20OCT92) 40-30-7 K Series Air Cooled Engine AllTractorManuals.com 220596 PN=354 BENCH TEST SOLENOID DRIVE STARTER—FC400V/FC420V/FC540V NOTE: Perform bench test before disassembling starter motor to determine cause of problem. IMPORTANT: Never operate motor longer than 20 seconds. Allow at least two minutes for cooling and battery recovery before operating again. Overheating, caused by excessive operation, will seriously damage starting motor. 1. Disconnect battery leads from battery. 2. Remove starter from engine. 3. Connect 12-volt battery (A) to starter battery terminal (B) and starter frame (C) using heavy duty cables. -UN-29AUG88 4.
Connect remote start switch (D) between switch terminal (E) and battery terminal (B). NOTE: A short piece of wire with a small clip on the end will allow a more positive connection at the M37149 switch terminal. When switch is activated, starter should engage and run. A—12-Volt Battery IF SOLENOID CHATTERS; hold-in winding is B—Battery Terminal open-circuited. C—Starter Frame D—Remote Start Switch IF NOTHING HAPPENS; either the solenoid pull-in E—Switch Terminal winding is open-circuited or mechanical parts are sticking. IF SOLENOID ENGAGES, BUT MOTOR DOES NOT RUN; check solenoid switch continuity, brushes, armature and field windings. Solenoid cannot be repaired, replace it.