High-pressure pump TCD 2013 2V W 17-01-04 (1) Vibration damper Dimension I I 7,6 mm + 1.5 - 1.5 2 Dimension II 5,4 mm + 0.5 - 0.5 II (2) Connection rail (3) Connection high pressure pump 1 3 6 © 48217-0 Attention! Install high pressure line without tension. Pay attention to alignment of the high pres - sure pipes. Pipes which touch the bore (1) of the union nut must be renewed. 1 © 43980-1 ●Tighten union nuts (arrows) with special wrench. Stage 1: 10 Nm Stage 2: 60° + 15° ●Check the high-pressure line for perfect installation position. © 43981-0 © 02/2010 OBJ_DOKU-21787-001.fm 7/10