High-pressure pump TCD 2013 2V W 17-01-05 Attention! The high-pressure line must always be renewed after disassembly. Install high pressure line without tension. ●Mount new high-pressure line on high-pressure pump and rail. ●Screw on union nuts (1). 1 Do not tighten union nuts. ●Check the high-pressure line for perfect installation position. 6 © 43995-0 Installation position of vibration damper. Attention! Pay attention to installation position. Do not turn vibration damper (1). (1) Vibration damper 1 X Dimension X 2 Diameter:
32 mm (2) Connection rail (3) Connection high pressure pump 3 © 48208-0 (1) Vibration damper Dimension I I 7,6 mm + 1.5 - 1.5 2 Dimension II 5,4 mm + 0.5 - 0.5 II (2) Connection rail (3) Connection high pressure pump 1 3 © 48217-0 © 02/2010 OBJ_DOKU-21788-001.fm 7/10