Deutz — Check alignment of connection housing

Connection housing TCD 2013 2V W 52-01-02 Position (III) III ●Turn the crankshaft slowly to position (III). ●Read off measured value. ●Note measured value, dimension (b). Note the sign! ●Note the measured value (b) with the appropriate sign on the measurement sheet. 6 © 47691-0 Position (IV) ●Turn the crankshaft slowly to position (IV). ●Read off measured value. ●Note the measured value, dimension (c). Note the sign! IV ●Note the measured value (c) with the appropriate sign on the measurement sheet. © 47692-0 ●Turn the crankshaft slowly to position (I). ●The dial gauge must indicate measured value "0" again. ●Make the calculation according to the example in ta - ble 1.

In case of a radial run-out deviation above the specified run-out limit value, the con - nection housing must be disconnected. I © 47688-0 © 02/2010 OBJ_DOKU-21820-001.fm 3/6