Deutz — Check alignment of connection housing

Connection housing TCD 2013 2V W 52-01-02 Measurement sheet - connection housing / radial run-out limit value 6 © 02/2010 OBJ_DOKU-21820-001.fm 6/6 SAE 4 361,95 0,25 SAE 5 314,32 0,25 Issued by: Date: Engine number: Connection housing:

Position (I) (II) (III) (IV) 1 Display on dial gauge 100410 0 a = b = c = 1a Arithmetic value (reversal of the sign) a1 = b1 = c1 = 2 Correction radial bearing clearance (d) (d) = 0.06 mm - - d = - 3 Half of the bearing clearance correction (d/2) - d/2 = - d/2 = 4 Corrected vertical total dial gauge display (L ) v L = v 5 Corrected horizontal dial gauge display (E1, E2) - E = 1 - E = 2 6 Horizontal total dial gauge display (L ) H L = H Calculation L = b1 + d v L = v E = a1 + d/2 1 E = 1 E = c1 + d/2 2 E = 2 L = E - E H 1 2 L = H L = R L = determined radial run-out limit value (t) R t = Connection housing SAE size (t) Radial run-out limit value (mm) Radial run-out alignment in order New alignment necessary Nominal Actual SAE 0 0,45 SAE 1 0,36 SAE 2 0,31 SAE 3 0,29 SAE 4 0,25 SAE 5 0,25