hitachi — MAINTENANCE STANDARD

UNDERCARRIAGE / Track MAINTENANCE STANDARD Link Measure the length of four links. 1. Do not measure the part included the master pin. 2. Measure the length with tension on the track. W155-03-07-001 ZAXIS450-3, 450LC-3, 470H-3, 470LCH-3 Unit: mm (in) Remedy A B Cladding by welding and finish or replace ZAXIS500LC-3, 520LCH-3 Remedy A B Cladding by welding and finish or replace [ ] Reference Master Pin W800-03-07-028 ZAXIS450-3, 450LC-3, 470H-3, 470LCH-3 Unit:

mm (in) Remedy A B C Replace ZAXIS500LC-3, 520LCH-3 [ ] Reference W3-7-13 A B Standard Allowable Limit 863.6 (34) [905.3 (35.6)] 129 (5.1) [122 (4.8)] Standard Allowable Limit 915.5 (36) [944.3 (37.2)] 134.6 (5.3) [127.6 (5.0)] C B C A Standard Allowable Limit 254 (10) - 47.3 (1.86) [44.3 (1.74)] 47.57 (1.87) - Standard Allowable Limit Remedy A 290 (11.4) - Replace B 48.5 (1.91) [45.5 (1.79)] C 48.83 (1.92) -