4.2 WATER PUMP (GEAR-CASE MOUNTED - 1991 AND LATER) (GCM) NOTICE: Do not allow brass drift to score housing bore when tapping out seals. A scored bore will cause coolant leaks and can damage engine. CHEMICAL BURNS To avoid injury from chemical burns, wear a face shield and neoprene or PVC gloves when handling fluoroelastomer O-rings or seals that have been degraded by excessive heat. Discard gloves after handling degraded fluoroelastomer parts. 8. Remove both the water and oil seals from the housing using a brass drift and hammer. 9. Support the drive shaft assembly on two steel blocks, at the bearing inner race. (Rev. 2005) All information subject to change without notice.
4-12 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION