Detroit Diesel — Print Preview - C:\DOCUME~1\llakso01\LOCALS~1\Temp\.aptcache\S600507006\S600507

SERIES 60 SERVICE MANUAL To avoid injury from flying parts when working with components under spring tension, wear adequate eye protection (face shield or safety goggles). EYE INJURY 8. If spring type hose clamps are used, fasten the bypass tube to the water pump bypass outlet and thermostat housing water inlet as follows: [a] Using the hose clamp installer tool (J–41454), install two hose clamps onto the water bypass tube; then push a connecting hose onto each end of the bypass tube. See Figure 4-31. Using hose clamp installer tool (J–41454), open the clamps and slide them over the hoses to secure them in place on the tube. Figure 4-31 Clamp Installer Tool NOTE:

Ensure the clamps are seated against the beads on the bypass tube neck and are at least one-half inch from the hose ends. [b] Using J–41454 (if required), install one clamp over the water bypass outlet on the water pump and one clamp over the thermostat housing water inlet. All information subject to change without notice. (Rev. 2005) 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION 4-31