Detroit Diesel — Print Preview - C:\DOCUME~1\llakso01\LOCALS~1\Temp\.aptcache\S600507006\S600507

SERIES 60 SERVICE MANUAL 4.3 WATER PUMP (FRONT MOUNTED) (FM) The centrifugal-type water pump circulates the engine coolant through the cylinder block, cylinder head, radiator and the oil cooler. See Figure 4-32. The pump is mounted on the front of the engine gear case cover on units built prior to 6R037024 and is driven by the water pump drive gear. The water pump drive gear meshes with the bull gear. Figure 4-32 Front Mounted Water Pump An impeller is pressed on one end of the stainless steel drive shaft. The other end of this shaft has internal threads, and a retaining bolt secures the water pump drive gear to the shaft.

Two identical roller bearing assemblies are used to carry the shaft See Figure 4-33. All information subject to change without notice. (Rev. 2005) 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION 4-33