Detroit Diesel — Print Preview - C:\DOCUME~1\llakso01\LOCALS~1\Temp\.aptcache\S600507006\S600507

4.3 WATER PUMP (FRONT MOUNTED) (FM) NOTICE: Form-a-Gasket Sealer must be used sparingly, and kept from the shaft and bearing surfaces. Excessive amounts of Form-a-Gasket Sealer could cause plugging of radiator or cooler core. 11. Turn the water pump housing over. Working through the front, apply a coating of Aviation Form-a-Gasket, Form-a-Gasket No. 3 or equivalent to the area where the water pump seal case contacts the pump body. See Figure 4-49. Figure 4-49 Sealer Installation 12. Install J–35988–3A (part of tool set J–35988–C) to the fixture tool. See Figure 4-50. Figure 4-50 Support Installation (FM) (Rev. 2005) All information subject to change without notice.

4-50 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION