SERIES 60 SERVICE MANUAL 5.4 COOLANT The coolant provides a medium for heat transfer and controls the internal temperature of the engine during operation. In an engine having proper coolant flow, some of the heat of combustion is conveyed through the cylinder walls and the cylinder head into the coolant. Without adequate coolant, normal heat transfer cannot take place within the engine, and engine temperature rapidly rises. Therefore, coolant must be carefully selected and properly maintained. The following terms are used throughout this section and must be understood. Coolant - The fluid mixture circulating in the engine cooling system.
IEG - Full strength (non-diluted) Inhibited Ethylene Glycol meeting applicable heavy-duty formulation specifications. IPG - Full strength (non-diluted) Inhibited Propylene Glycol meeting applicable heavy-duty formulation specifications. SCA - Supplemental Coolant Additives. Used to prevent corrosion, cavitation, and the formation of deposits. Initial fill - Any time the cooling system is empty, then filled with new coolant. Precharged IEG - Also referred to as a fully formulated IEG. Contains the proper amount of SCA. Additional SCA must not be used with a precharged IEG at initial fill. Precharged IPG - Also referred to as a fully formulated IPG. Contains the proper amount of SCA.
Additional SCA must not be used with a precharged IPG at initial fill. Dropout - Sludge or deposit formation in or on cooling system components. Using a coolant with the appropriate concentrations of SCA is one of the most important aspects of quality engine maintenance. To achieve the chemical balance needed to protect a cooling system, certain coolant basics must be understood. This section provides the directions and information required to ensure cooling system protection for Detroit Diesel Series 60 engines. These recommendations are general rules and reflect the current technology. Specific concerns not covered should be addressed to your local Detroit Diesel representative.
The coolant used in Detroit Diesel Series 60 engines must meet the following basic requirements: Provide an adequate heat transfer medium. Protect against cavitation damage. Provide a corrosion/erosion-resistant environment. Prevent formation of scale or sludge deposits. Be compatible with cooling system hose and seal materials. Provide adequate freeze protection. A properly maintained coolant can be used up to the intervals listed in Table 5-19. At this time the cooling system must be drained, thoroughly cleaned and filled with new coolant. To achieve these requirements, coolants are mixtures of good quality water, SCA and often an IEG or IPG for freeze protection.
The rest of this bulletin will describe the requirements and usage of the water, SCA, IEG, and IPG. All information subject to change without notice. (Rev. 2005) 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION 5-17