Detroit Diesel — Print Preview - C:\DOCUME~1\llakso01\LOCALS~1\Temp\.aptcache\S600507006\S600507

SERIES 60 SERVICE MANUAL Table 5-15 Coolant Inhibitor Element Size Requirements-Maintenance Dosage for IEG, IPG, Precharged, and Water-Only Coolant Mixture The concentration of SCA will gradually deplete during normal engine operation. Check the SCA concentration at the regular intervals listed in Table 5-16. Additional SCA must be added to the coolant when it becomes depleted below a specified level (listed in Table 5-17). Maintenance dosage of SCA must only be added if nitrite concentration is less than 800 ppm. If nitrite concentration is greater than 800 ppm, do not add additional SCA.

Due to the elevated fire deck temperatures in the Series 60G engine, it is very important that the phosphorus (P) level remain below the maximum. Operation of the Series 60G engine with phosphorus levels above the maximum will lead to phosphorus dropout on the hot firedeck surfaces. This dropout will form an insulation layer between the fire deck and coolant, and lead to eventual engine damage. Table 5-16 Required Coolant Inhibitor Test Intervals Table 5-17 SCA Limits with GM6038-M or ASTM-D 4985 (50/50 Coolant/Water Mixture) 5.4.4 Soluble Oils Soluble oil additives are not approved for use in the Detroit Diesel Series 60 engine cooling systems.

A small amount of oil adversely affects heat transfer. A 1.25% concentration of soluble oil increases the fire deck temperature 6%. A 2.50% concentration increases the fire deck temperature 15%. All information subject to change without notice. (Rev.

2005) 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION 5-25 Cooling System Capacity, L (Gallons) Fiter Quantity Filter Part Number Liquid Only Number of Pints 34-45 (9-12) 1 23507545 1/2 - 3/4 49-61 (13-16) 1 23507545 3/4 - 1 Service Application Inhibitor Test Interval On-highway Trucks and Motor Coaches 33,000 km (205,000 miles) City Transit Coaches, Pick-up and Delivery, Short Trip, and Emergency Vehicles 9,600 km (6,000 miles) or three months, whichever comes first. SCA Minimum SCA ppm Maximum SCA ppm Boron (B) 1,000 1,500 Nitrite (NO ) 2 800 2,400 Nitrates (NO ) 3 1,000 2,000 Silicon (Si) 50 250 Phosphorus (P) 0 500 pH 8.5 10.5