SERIES 60 SERVICE MANUAL 6.4.1 Replacement of the Closed Crankcase Breather The Crankvent coalescing filter is a nonserviceable component but should be changed in conjunction with oil service intervals. Refer to section 14.4.3. 6.4.2 Removal of Closed Crankcase Breather Remove the closed crankcase breather as follows: 1. Release latches on the side of the breather assembly and lower canister away from the assembly. 2. Remove the filter from the assembly. 3. Dispose of the used filter in an environmentally responsible manner. 4. Clean the filter canister with a clean lint-free cloth. 6.4.3 Installation of the Closed Crankcase Breather Filter Install the closed crankcase breather filter as follows:
1. Insert new filter into the top of the assembly, ensuring the new filter contains the top O-ring. See Figure 6-10. 2. Replace the lower canister ensuring the larger O-ring is secure in the top half of the assembly. 3. Secure the latches on the side of the can. 4. There are two O-rings in the system. One on the filter element itself and one that seals between the lower canister and the upper body. Ensure both O-rings are secure before reassembling the crankvent. All information subject to change without notice. (Rev. 2005) 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION 6-19