Detroit Diesel — Print Preview - C:\DOCUME~1\llakso01\LOCALS~1\Temp\.aptcache\S600507006\S600507

6.6 TURBOCHARGER SERIES 60 NATURAL GAS (AUTOMOTIVE) ENGINE 2. Remove the retaining clip that holds the actuator rod end on the wastegate lever arm pin. NOTICE: For genset actuator, never apply pressure to the bottom side of actuator port. Damage to the actuator may result. 3. Using pressure gage setup (see Figure 6-31) apply enough pressure to the top side actuator can port until the rod begins to move, lifting the wastegate valve off of it's seal. 4. Slip rod end off the wastegate lever arm pin. 5. Adjust rod as needed To INCREASE pressure setting at 0.04 in. turn rod end CLOCKWISE. To DECREASE pressure setting at 0.04 in. turn rod end COUNTERCLOCKWISE. 6.

With pressure still applied to actuator, replace rod end on wastegate lever arm 7. Check actuator set pressure again; refer to section 6.6.6. 8. If actuator is still out of adjustment, repeat this procedure again. 9. If actuator is within specified set pressure, re-install retaining clip on wastegate lever arm pin. 10. Tighten jam nut to secure rod end. (Rev. 2005) All information subject to change without notice. 6-58 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION