SERIES 60 SERVICE MANUAL 5. Connect the safety straps on the couplers to any convenient screw on the radiator mounting bracket. PRESSURIZED AIR AND FLYING PARTICLES To avoid injury to eye or face, wear a face shield or goggles when conducting a pressure test. 6. Attach an air pressure line, with filtered air, to the air shutoff valve and gradually pressurize the charge air cooler to a pressure of 205 kPa (30 psi). If necessary, perform the following steps to adjust the air regulator until the gauge reads 205 kPa (30 psi): [a] Pull regulator knob outward to unlock. [b] Turn knob to adjust pressure to 205 kPa (30 psi). [c] Push the regulator knob back into locked position. 7.
Close the air shutoff valve and monitor the gauge with a stop watch for 15 seconds. Note any decrease in air pressure. 8. Repeat test at least three times to verify results. [a] If the pressure drop is 34 kPa (5 psi) or less in 15 seconds the cooler is good. [b] If the pressure drop is greater than 34 kPa (5 psi) in 15 seconds, replace the charge air cooler. Refer to6.8.1. 9. Slowly release pressure with the charge air cooler by opening the valve in the bleed-off coupler. 10. Remove all charge air cooler tester pieces and reconnect charge air cooler piping to the engine. 11. Reconnect air inlet and outlet piping to engine. Torque hose clamps to 5.6 - 6.78 N·m (50 - 60 lb·in).
6.8.2.3 Turbocharger Failure Clean-up Procedure When a turbocharger failure occurs, debris and oil are deposited into truck components. It is necessary to properly clean the engine and related components to ensure additional damage does not occur. All information subject to change without notice. (Rev. 2005) 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION 6-69