Detroit Diesel — Print Preview - C:\DOCUME~1\llakso01\LOCALS~1\Temp\.aptcache\S600507006\S600507

SERIES 60 SERVICE MANUAL 9.8 METRI-PACK 150 SERIES CONNECTORS Metri-Pack 150 series connectors are "pull-to-seat" connectors. Each wire must be pushed through the connector prior to crimping the terminal. Cable seals are inserted into the shell of the connector and hold many wires. 9.8.1 Repair and Replacement of Metri-Pack 150 Series Connectors Repairs to Metri-Pack 150 series connectors are not possible. Remove the defective or damaged connector and replace. Refer to section 9.8.2. 9.8.2 Removal of Metri-Pack 150 Series Connectors A tang on the terminal locks into a tab molded into the plastic connector to retain the cable assembly.

Remove and repair Metri-Pack 150 terminals using the following instructions. 1. Insert the removal tool into the cavity of the connector, placing the tip of the tool between the locking tang of the terminal and the wall of the cavity. See Figure 9-30. Figure 9-30 Terminal Removal 2. Depress the tang of the terminal to release it from the connector. 3. Push the cable forward through the terminal until the complete crimp is exposed. 4. Cut the cable immediately behind the damaged terminal to repair it. 5. Follow the installation instructions for crimping the terminal and inserting it into the connector. All information subject to change without notice. (Rev.

2005) 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION 9-53