Detroit Diesel — Print Preview - C:\DOCUME~1\llakso01\LOCALS~1\Temp\.aptcache\S600507006\S600507

9.9 MICRO-PACK SERIES CONNECTORS 9.9 MICRO-PACK SERIES CONNECTORS Micro-Pack series connectors are push-to-seat connectors. Each wire must be crimped into the terminal before it is inserted into the connector. All terminals require 18 gage GXL wire. 9.9.1 Repair and Replacement of Micro-Pack Connectors Repairs to Micro-Pack connectors are not possible. Remove the defective or damaged connector and replace. Refer to section 9.9.2. 9.9.2 Removal of Micro-Pack Connectors To remove the connector: 1. Cut the cable immediately behind the damaged terminal. 2. Install a fresh connector. Refer to section 9.9.3.

9.9.3 Installation of Micro-Pack Connectors Micro-Pack series connectors are of the push-to-seat design. The terminal is crimped on the wire before it is inserted into the connector. Use the following instructions for terminal installation: NOTICE: The cable should be stripped of insulation before it is inserted through the connector body. 1. Strip the end of the cable using wire strippers to leave 5.0 mm ± 0.5 (0.20 in ± 0.02) of bare conductor. 2. Insert the terminal into the locating hole of the crimping tool. Check the gage of the cable to locate the proper hole. (Rev. 2005) All information subject to change without notice. 9-58 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION