Detroit Diesel — Print Preview - C:\DOCUME~1\llakso01\LOCALS~1\Temp\.aptcache\S600507006\S600507

13.4 VALVE LASH FOR THE SERIES 60G ENGINE 6. To adjust the intake valves, insert a 0.279 mm (0.011 in.) feeler gage between the tip of the valve stem and the valve button at the end of the rocker arm. See Figure 13-16. 1. Feeler Gage 4. Wrench (9/16 in.) 2. Valve Button 5. Intake Valve Stem 3. Allen Wrench (3/16 in.) Figure 13-16 Valve Clearance Adjustment Series 60G Engines 7. Loosen the locknut, and turn the adjusting set screw until the feeler gage produces an even or smooth pull between the valve stem and the valve button. 8. Torque the locknut to 41-47 N·m (30-35 lb·ft), and remove the feeler gage.

Insert the feeler gage to ensure that the adjustment did not change when the locknut was tightened. Readjust as necessary. 9. The exhaust valves are adjusted the same way as the intake valves, except that a 0.914 mm (0.036 inch.) feeler gage is used. 10. Complete the adjustment of all four valves (two intake, two exhaust) for that cylinder before proceeding to the next step. 11. See Figure 13-15 and note the cylinder number, in parentheses, directly under the cylinder that just received the valve adjustment. (Rev. 2005) All information subject to change without notice. 13-28 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION