Detroit Diesel — Print Preview - C:\DOCUME~1\llakso01\LOCALS~1\Temp\.aptcache\S600507006\S600507

14.6 DESCRIPTION OF MAINTENANCE ITEMS 14.6.1 Lubricating Oil Check the lubricating oil level with the engine stopped and the vehicle on level ground. If the engine has just been stopped and is warm, wait approximately ten minutes to allow the oil to drain back to the oil pan. Add the proper grade oil as recommended to maintain the correct oil level on the dipstick. Refer to section 5.2.1. NOTE: Do not overfill. Oil may be blown out through the crankcase breather if the crankcase is overfilled. Make a visual check for oil leaks around the filters and the external oil lines. Change the lubricating oil as follows: 1. Position the vehicle or equipment on level ground. 2.

If the engine is cold, run it until it is warm. NOTICE: When removing or installing a side plug, hold the flats of the insert with a 2 1/8 in., or larger, open end adjustable wrench to keep it from turning. If the insert is loosened, it may be necessary to remove the oil pan and retighten the nut to prevent a possible oil leak. 3. Remove drain plug on the bottom of oil pan. Drain lube oil into a suitable container. Always dispose of used lubricating oil in an environmentally responsible manner, according to state and/or federal (EPA) recommendations. NOTE:

If the lubricating oil is drained immediately after an engine has been run for some time, most of the sediment will be in suspension and will drain readily. 4. Coat drain plug(s) with Loctite® PT 7271 sealant (or equivalent). Install and torque to 45-56 N·m (33-41 lb·ft). (Rev. 2005) All information subject to change without notice. 14-22 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION