15.1 PREPARING ENGINE FOR STORAGE 15.1.1 Temporary Storage (30 Days or Less) To protect an engine for a temporary period of 30 days or less, proceed as follows: 1. Drain the engine crankcase. Refer to section 14.6.1. 2. Fill the crankcase to the proper level with the recommended viscosity and grade of oil, listed in Table 15-2. 3. Fill the fuel tank with the recommended grade of fuel oil, listed in Table 15-3. Operate the engine for two minutes at 1200 rpm and no load. NOTE: Do not drain the fuel system or the crankcase after this run. 4. Check the air cleaner and service it, if necessary. Refer to OEM guidelines. 5.

If freezing weather is expected during the temporary storage period, add an ethylene glycol base antifreeze solution to the cooling system in accordance with the manufacturer's recommendations. Otherwise, the coolant system should be flushed and filled with a good rust inhibitor to prevent rusting of the outside diameter of the cylinder liners. Refer to section 14.6.4. 6. Remove electrical components. Refer to section 9. EYE INJURY To avoid injury from flying debris when using compressed air, wear adequate eye protection (face shield or safety goggles) and do not exceed 276 kPa (40 psi) air pressure. 7. Clean the engine exterior with fuel oil and dry the engine with compressed air. 8.

Seal all of the engine openings with a material used for this purpose. The material used for sealing must be waterproof, vapor proof and possess sufficient physical strength to resist puncture and damage from the expansion of entrapped air. (Rev. 2005) All information subject to change without notice. 15-4 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION