1.12 GEAR CASE PRE-EXHAUST GAS RECIRCULATION (EGR) 1.12.2.1 Inspection of Gear Case Clean all of the old gasket sealer from the mating surfaces of the gear case, gear case cover, and engine block. Refer to "Gasket Eliminator Removal," in the "General Information" section at the beginning of this manual. Clean the gasket material from the mating surfaces of any components or access covers that were removed from the gear case cover or gear case. Clean all of the parts with clean fuel oil and dry with compressed air. Remove the oil gallery plug at the edge of the gear case. See Figure 1-201.
EYE INJURY To avoid injury from flying debris when using compressed air, wear adequate eye protection (face shield or safety goggles) and do not exceed 276 kPa (40 psi) air pressure. Use compressed air to ensure the oil gallery is completely free of blockage. If necessary, use a wire brush to clean the gear case oil gallery. Inspect the gear case for stress cracks, breaks, or other damage. Repair or replace as necessary. Inspect the adjustable idler gear studs for signs of galling or scoring. Replace as necessary. Inspect all the individual components as outlined under the appropriate section. 1.12.3 Installation of Gear Case Use the following instructions for gear case installation: 1.
Apply a thin film of gasket eliminator PT-7276 (Loctite® 518) or equivalent to the cylinder block. See Figure 1-208. Carefully smooth the bead around the block-to-gear case oil passage to avoid contamination. NOTE: The installation of Gasket Eliminator to the gear case-to-block mating surfaces at the top of the block is critical. Excess gasket eliminator material can extrude into the oil passage between the block and gear case, causing early failure of components. In addition, the (Rev. 2005) All information subject to change without notice. 1-222 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION