2.33 COOLANT LEVEL SENSOR 2.33.1 Replacement of Coolant Level Sensor Both the CLS sensor probe and module are non-serviceable and should be replaced as necessary. 2.33.2 Removal of Coolant Level Sensor Remove the CLS as follows: 1. Open the drain cock at the bottom of the radiator and drain the coolant into an appropriate container. Remove only as much coolant as is necessary to clear the CLS probe. 2. Remove ground wire screw and ground wire from side of probe. 3. Loosen and remove nut from sensor lead of probe. 4. Remove sensor lead, or unplug the two-pin connector. 5. Use the appropriate wrench on the hex portion of the sensor and unscrew it from the radiator.

2.33.3 Installation of Coolant Level Sensor Probe Install the CLS Probe as follows: 1. Install CLS probe into the radiator or heat exchanger as follows: NOTE: New sensors are pre-coated with a thread sealer. If sensor is new, no additional sealant is required. If sensor is reused, apply Loctite® 567 pipe sealant with Teflon® or equivalent. Loctite® is a registered trademark of the Loctite Corporation. Teflon® is a registered trademark of the E. I. DuPont de Nemours and Company, Inc. [a] Install and torque vehicle engine CLS to 11–14 N·m (8–10 lb·ft). 2. Connect the two-pin connector. 3. Fill the cooling system. Refer to section 14.6.4. 4. Turn the ignition to the ON position.

Observe or read any diagnostic code(s). If any code other than code 25 appears, refer to the DDEC Troubleshooting Guide: 6SE477 (DDEC I), 6SE489 (DDEC II), or 6SE497 (DDEC III/IV). (Rev. 2005) All information subject to change without notice. 2-200 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION