2.36 EXHAUST GAS OXYGEN SENSOR FOR SERIES 60G ENGINES 2.36.3 Installation of the Exhaust Gas Oxygen Sensor and the Oxygen Sensor Interface Module Install the exhaust gas oxygen sensor as follows: NOTICE: Use of excessive amount of anti-seize compound or direct sensing element contact with compound can cause sensor poisoning and erroneous sensor readings or failure. 1. New sensors have antiseize compound pre-applied to the threads of the sensor. If reinstalling a used sensor, lightly apply antiseize compound to threads of sensor. 2. Install sensor in boss and torque to 40–50 N·m (29.5–36.9 lb·ft). 3. Connect oxygen sensor harness to sensor. 4.
Turn on ignition and, with the Diagnostic Data Reader, clear the AFR (air fuel ratio) learn table. 5. Start engine and check for check engine or stop engine light. Install the oxygen sensor interface module as follows: 1. Position module on sensor bracket and install three M6 attaching bolts. 2. Connect to three-pin and two-pin connectors in engine sensor wire harness. 3. Connect to six-pin connector in oxygen sensor wire harness. 4. Turn on ignition and, with the Diagnostic Data Reader, clear the AFR (air fuel ratio) learn table. 5. Start engine and check for check engine or stop engine light or read any diagnostic codes.
If any code other than 25 is obtained, refer to the Detroit Diesel Single ECM Troubleshooting Manual (6SE497). (Rev. 2005) All information subject to change without notice. 2-210 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION