2.42 VENTING AND LEAK CHECKING PROCEDURES FOR A NATURAL GAS ENGINE (HIGH PRESSURE SYSTEM) 2. Repair any leak by: [a] Tightening connection using the fitting technique of the manufacturer. NOTE: Bleed the fuel lines before replacing leaking components using the procedure in this section. This will prevent a discharge of gas. [b] Replacing leaking component. [c] Replace the pipe threaded connector with a new one if the leak is a pipe thread con- nection. Use anaerobic sealant with Teflon (such as SWAK®) applied to the threads. SWAK® is a registered trademark of The Cajon Company. 3. Re-check connection with procedure in step1. 4.
Use a combustible gas detector to check for presence of natural gas. If natural gas is detected, continue looking for leaks until the locations of all the leaks are determined. 5. Repair the leak using the procedure in step 2. (Rev. 2005) All information subject to change without notice. 2-228 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION