2.47 IMPCO LOW PRESSURE FUEL REGULATOR FOR THE SERIES 60G ENGINE HIGH PRESSURE FUEL SYSTEM 2.47.2 Removal of the Low Pressure Regulator for the Series 60G Engine Remove the low pressure fuel regulator as follows: EXPLOSION To avoid injury from the explosion of natural gas, the engine must be kept in a well ventilated area away from open flames, sparks, and electrical resistance (heating) coils. 1. Vent fuel system, refer to section 2.51. 2. Disconnect fuel supply hose at the regulator. 3. Disconnect fuel pressure sensor from engine sensor wiring harness. 4. Drain coolant. 5. Disconnect coolant supply and return hoses at regulator. 6. Disconnect air balance hose at regulator cover. 7.
Remove two M6 regulator to air inlet elbow mounting bolts. Support regulator to avoid cocking the connector tube in the PSV and possibly damaging the PSV gas inlet bore. 8. Slide regulator rearward to disengage outlet connector tube from the PSV. 9. Remove gas inlet tee, fuel pressure sensor, coolant inlet fittings, coolant outlet fittings, balance hose fitting, outlet connector tube and O-rings for reuse. 2.47.3 Installation of the Low Pressure Regulator for the Series 60G Engine Install the low pressure fuel regulator as follows: NOTICE: Use caution when installing hoses to avoid twisting or kinking the hose. This could result in increased flow restriction and affect engine performance. (Rev.
2005) All information subject to change without notice. 2-240 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION