2.47 IMPCO LOW PRESSURE FUEL REGULATOR FOR THE SERIES 60G ENGINE HIGH PRESSURE FUEL SYSTEM 3. Position regulator on air inlet elbow with outlet connector aligned with bore in PSV. Slide regulator forward engaging outlet tube in PSV until regulator mounting bolt holes are aligned. 4. Install two M6 mounting bolts. 5. Connect fuel supply hose. 6. Connect coolant supply and return hoses. 7. Refill with coolant. 8. Connect air balance hose. 9. Connect fuel pressure sensor to engine sensor wiring harness. 10. Clear AFR learn table using DDR. 11. Start engine and check hoses and fitting for leaks. Refer to section 2.39.3. (Rev. 2005) All information subject to change without notice.
2-242 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION