Detroit Diesel — Print Preview - C:\DOCUME~1\llakso01\LOCALS~1\Temp\.aptcache\S600507006\S600507

2.48 OVERVIEW OF THE LOW PRESSURE NATURAL GAS FUEL SYSTEM To avoid injury from the explosion of natural gas, the engine must be kept in a well ventilated area away from open flames, sparks, and electrical resistance (heating) coils. EXPLOSION The Series 60 natural gas engine low pressure fuel system consists of a venturi type fuel mixer, Pulsewidth Modulated Stepper Motor Valve (PSV), and low pressure regulator. It is referred to as a "demand" system in that the venturi mixer generates a suction at the regulator outlet. The regulator adjusts its outlet pressure in response to the demand (suction) of the venturi resulting in an increase of fuel flow.

The opposite is true for conditions requiring a decrease in fuel flow. See Figure 2-143. Figure 2-143 Low Pressure Natural Gas Fuel System (Series 60G Engine) (Rev. 2005) All information subject to change without notice. 2-246 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION