Perkins — Wiring diagram maximum circuit resistance

14 400 Series Wiring diagram 15 amp alternator - 403C-11 Wiring diagram maximum circuit resistance The resistance of battery cables 1, 2 and 3 must not exceed 0.0018 . Note: If a glow signal is not used - it is still necessary to connect terminal 19 and 17 on the switch. 1 Alternator warning lamp 2 Regulator 10 Fuse 9 Thermostat switch 3 Alternator 11 Key switch 4 Battery 12 Glow signal 5 Starter motor 6 Oil pressure warning lamp 13 Glow plugs 14 Solenoid switch 7 Oil pressure switch (1) 15 A delayed fuse can be fitted if required 8 Water temperature warning lamp (1) Max current draw for standard oil pressure switch is 0.42 amps (5 Watt lamp max). = Diode. Capacity: Current 3 amp.

Reverse Voltage: 600V. (This is mandatory) . 14 1 6 8 Sb G Y 9 7 13 3 2 R Sb B 10 B 15 AC 17 30 50 19 12 4 5 S 11 108 Workshop Manual, TPD 1458E, issue 3 - Perkins Confidential: Green Circuit Cable number Circuit current Maximum circuit resistance Maximum cir- cuit volt drop Remarks lternator harging 14 amp (2 cyl) 15 amp (3 cyl) 0.036  (2 cyl) 0.033  (3 cyl) 0.5 Volt See Glow Plugs Circuit tarter motor olenoid 15.75 amp 0.04  0.63 Volt See Glow Plugs Circuit TD glow plugs ia glow signal) (Peak max) 26 amp (2 cyl) 39 amp (3 cyl) 0.0192  (2 cyl) 0.0128  (3 cyl) 0.5 Volt