400 Series 14 Wiring diagram 40 amp alternator - 403C-11 Wiring diagram maximum circuit resistance The resistance of battery cables 1,2 and 3 must not exceed 0.0018 . 1 Alternator warning lamp 9 Key switch 2 Alternator 10 Glow signal 3 Battery 11 Glow plugs 4 Starter motor 5 Oil pressure warning lamp 12 Fuse 13 Fuse 6 Oil pressure switch (1) 14 Solenoid switch 7 Water temperature warning lamp 15 A delayed fuse can be fitted if required 8 Thermostat switch (1) Max current draw for standard oil pressure switch is 0.42 amps (5 Watt lamp max). = Diode. Capacity: Current 3 amp. Reverse Voltage: 600V. (This is mandatory) .
14 1 5 7 2 11 N 6 8 F B 12 13 B 15 AC 17 30 50 19 10 3 4 S 9 Workshop Manual, TPD 1458E, issue 3 - Perkins Confidential: Green 109 Circuit Cable number Circuit curren Maximum circuit t resistance Maximum cir- cuit volt drop Remarks Alternator charging 40 amp 0.0125 s 0.5 Volt See Glow Plugs Circuit Starter motor solenoid 15.75 amp 0.04 s 0.63 Volt See Glow Plug Circuit STD glow plugs (via glow signal) (Peak max) 39 amp 0.0128 s 0.5 Volt