Perkins — Charging circuit

14 400 Series Wiring diagram 55 amp alternator 403C-15, 404C-22 and 404C-22T Charging circuit Caution: Diode capacity: current 3 amps, reverse voltage 600V this is mandatory . Notes: Maximum cable size for 375 Lucar terminals on the alternator is 65/0,3 mm (4,5 mmІ) therefore twin cables are required at connection to the alternator. Maximum current draw for standard oil pressure switch is 0.42 amps (5 Watts maximum bulb). A delay fuse can be fitted if necessary. Alternator charge lamp, 55 amps Alternator charge lamp rating: 12V - 2,2W at 850 rev/min. When the engine is stopped the alternator charge lamp is illuminated via the battery.

The light is extinguished when the engine is operated and the alternator is generating. The use of a lower wattage bulb than the rating above will increase the speed at which the alternator will operate. e.g. a charge lamp with a lower wattage bulb will have a rating of 12V - 1,2W at 1300 rev/min. D2 2 DIODE Oil press. Altr. Water temp. D1 1 Solenoid switch Alternator 2 diode Oil press. switch Thermo switch W 11 Glow plugs 10 B+ B IND 7 Fuse 1 65A 80/0.4 (10) 9 B 4 3 5 AC 30 17 3 2 Glow signal Key switch 19 50 8 Starter motor 12V Battery S 6 K1091/2 110 Workshop Manual, TPD 1458E, issue 3 - Perkins Confidential:

Green Circuit Cable number Circuit current Maximum circuit resistance Maximum circuit volt drop Remarks Alternator charging 4, 7, 11 55 Amps 0.0143 ohm 0.50 Volt See glow plugs circuit Starter motor solenoid 4, 5, 6 15.75 Amps 0.0400 ohm 0.63 Volt See glow plugs circuit STD glow plugs (via glow signal) 4, 5, 8, 9, 10 (Peak max) 52 Amps 0.0139 ohm 0.50 Volt -