400 Series 14 Automatic shutdown connector 55 Amp alternator charge lamp Note: Alternator charge lamp rating: 12V - 2.2W at 850 rev/min. When the engine is at rest the alternator charge lamp is illuminated via the battery and it extinguishes when the alternator operates. The use of a lower wattage bulb than the above will increase speed at which self excitation occurs upon initial run up, e.g. a charge lamp with a lower wattage bulb will have a rating of 12V - 1.2W at 1300 rev/min. 1 2 3 4 5 6 Connector H1116 Workshop Manual, TPD 1458E, issue 3 - Perkins Confidential:
Green 111 Pin number connector Wire colour Connection 1 Red Key switch - AC 2 Orange Key switch - 50 3 Red / Black Solenoid 4 Brown Oil pressure switch 5 Blue Coolant temperature switch 6 Black Ground (Earth)