24.2.10 CHECK, ADJUST AIR CONDITIONER I Compressor pulley I CHECKING TENSION OF COMPRESSOR BELT If the belt is loose, it will slip and the cooling effect will be reduced. From time to time, press a point midway between the drive pulley and compressor pulley with your finger (approx. 10 kg (22.05 lb)) and check that the tension is 13 - 17 mm (0.51 - 0.67 in). When the belt is new, there will be initial elongation, so always adjust again after 2 or 3 days. Drive pulley AD106080 CHECK LEVEL OF REFRIGERANT (GAS) The refrigerant used in the cooler is colorless and odorless and eyes or on your hands, it may cause loss of sight or frostbite, so never loosen any part of the refrigerant circuit.
If the level of the refrigerant (gas) is low, the cooling effect will be reduced. Run the engine at high idling, and check the flow of the refrigerant in the refrigerant circuit through the sight glass of the receiver @ when the cooler is running at high speed. l No bubbles in refrigerant flow: Correct l Bubbles in refrigerant flow (bubbles continuously pass through): Refrigerant level low l Colorless, transparent: No refrigerant REMARK When there are bubbles, the refrigerant gas level is low, so contact your refrigerant dealer to have refrigerant added. If the air conditioner is run with the refrigerant gas level low, it will cause damage to the compressor. !I% 0 I ,,I,~; Correct 0:‘:
0 Refri erant .‘:.P,: level ow 9 0 No refrigerant ( Colorless, transparent ) L-J Receiver AD053280 3-34