MAINTENANCE PLAN 4.7.5 MAINTENANCE AFTER THE FIRST 250 HOURS OF OPERATION These maintenance operations must be carried out after the first 250 hours of operation, together with those to be carried out “EVERY 250 HOURS”. CHANGE THE OIL IN THE TRAVEL REDUCTION GEARS CHECK AND ADJUST THE ENGINE VALVE CLEARANCE For further details on the various maintenance operations, see the sections “4.7.8 MAINTENANCE EVERY 1000 HOURS OF OPERATION” and “4.7.9 MAINTENANCE EVERY 2000 HOURS OF OPERATION”. For the inspection and adjustment, contact your Komatsu Dealer.
4.7.6 MAINTENANCE EVERY 250 HOURS OF OPERATION 3 RWA10610 160 To reach the fan belt, remove the inspection cover (1) (use a 17 mm spanner) and open the engine hood (see “3.5.1 ENGINE HOOD”). The check is manual: press the belt with your thumb on the indi- cated point with a force equal to approx. 60 N (13.5 lb); the result- ing deflection must be approximately 10-15 mm (0.4 to 0.6 in). If the deflection exceeds this value, loosen the screw (2) and the nut (3) that fasten the alternator (4) and, with a lever inserted be- tween the motor block and frame, make the alternator slide. Lock the screw and the nut and check again. Use 12 mm and 13 mm spanners.
A -Fan pulley B -Driving shaft pulley C -Alternator pulley 1 RWA10600 A C 10 ÷ 15 mm 1 RWA10600 A C 10 ÷ 15 mm IMPORTANT IMPORTANT • If the belt is worn, change it and check the tension again af- ter a few hours of operation. B RWA09220