Komatsu — 4.7.6.C CHECKING THE FUEL FILTER

MAINTENANCE PLAN 4.7.6.b CHECKING THE BATTERY ELECTROLYTE LEVEL WARNING Check the level only after stopping the engine and if necessary add distilled water only before starting work. Always wear safety goggles and waterproof gloves. To prevent gas explosions, do not use naked flames, do not smoke and avoid producing sparks due to short circuits. The battery electrolyte is dangerous; if it comes in contact with the eyes or skin, rinse with plenty of wa- ter and consult a doctor without delay. 4.7.6.c CHECKING THE OIL LEVEL IN THE TRAV- EL REDUCTION GEARS 161 The battery (1) can be reached by opening the right door (2).

The electrolyte level in each cell must be about 6 mm above the plate edge; if necessary, top up with distilled water only. If, on the contrary, the level is low because some fluid has been spilled, add diluted sulphuric acid until reaching the concentration suitable for the ambient temperature. (See “3.11.3 BATTERY”). 2 1 RWA10620 2 1 RWA10620 IMPORTANT IMPORTANT • It is advisable to add distilled water before starting work, in order to prevent it from freezing. • Before putting back the cell plugs, make sure that the breather holes are not clogged. • Make sure that the connection terminals are not oxidized; if necessary, clean them and cover them with anti-oxidation grease.

WARNING • As soon as the machine has been stopped the oil is very hot; let it cool down until it reaches 40-50°C before carrying out the check. This check must be carried out on each reduction gear positioned with the drain plug (1) downward and aligned with the level plug (2) on the vertical axis. If necessary, move the machine slightly until reaching the re- quired position, which must absolutely be respected in order to carry out a precise check. This check is visual: the oil must reach the hole (2); otherwise, top up following the procedures described in paragraph “4.7.8.a CHANGING THE TRAVEL REDUCTION GEAR OIL” and using the prescribed oil. (See “4.3 FUEL, COOLANT AND LUBRICANTS”).

Use a 8 mm setscrew spanner. 2 1 RWA09250