MAINTENANCE PLAN 4.7.9 MAINTENANCE EVERY 2000 HOURS OF OPERATION Carry out these operations together with those to be performed every 100, 250, 500 and 1000 HOURS. 169 WARNING RWA09270 RWA09270 • Retract the bucket and arm cylinder completely, lower the bucket teeth to the ground and, after stopping the engine, release the residual pressures from the work equipment circuits (by operating the controls more than once) and from the tank (by slowly loosening the filling cap). • Let the oil cool down until it reaches 40-45°C (104-113°F) before carrying out any maintenance operation. • Immediately clean any area dirty with oil.
• Oils, filters, the coolant and the battery are considered spe- cial waste and must be collected and disposed of accord- ing to the anti-pollution regulations in force. 1 - Rotate the upper structure of 45°, in such a way as to leave the lower part of the hydraulic oil tank free from the tracks. 2 - Retract the bucket and arm cylinder completely and lower the boom until the bucket teeth touch the ground. 3 - Lower the blade to the ground. 4 - Stop the engine and eliminate the residual pressures present in the equipment (by moving the controls several times).
5 - Remove the left cover (1) (use a 17 mm spanner), the lower cover (2) (use a 17 mm spanner), open the engine hood and slowly loosen the filling cap (3) in order to release the residual pressure (use a 24 mm spanner). 6 - Remove the drain plug (4) and let the oil flow out, gathering it in a container with suitable capacity. Use a 32 mm hexagon spanner. 7 - Loosen the clamps (5), remove the suction pipe (6) and let the remaining oil flow out of the tank. 8 - Remove the screws (7) and the flange (8) and clean the suc- tion filter (9). Use a 17 mm hexagon spanner.
RWA07490 1 RWA11010 RWA07490 IMPORTANT IMPORTANT • Carefully check the filtering element grid and if it is not in perfect conditions, change it. 2 RWA11050