MAINTENANCE PLAN 170 9 -Put back the drain plug (4) and the lower flange (8) with the filter (9), making sure that the gasket and the suction pipe (6) with the clamps (5) are in perfect conditions. 10 -Top up with the prescribed oil until reaching the level (10). To top up, use only the prescribed type of oil (see “4.3 FUEL, COOLANT AND LUBRICANTS”). 11 -Loosen the bleeding screw (11) positioned on the hydraulic pump, until no air bubbles can be seen in the oil that flows out of the screw. Use a 10 mm spanner. After bleeding the system, tighten the screw (11). Put back the filling cap (3).
12 -Extend the boom, arm and bucket cylinders completely, as indicated in the figure, and remove the filling cap (3). Put back the cap and pressurize the inside of the tank by lowering the equipment to the ground. 13 -Make sure that all the control levers are in neutral and let the engine idle for 2÷3 minutes before operating the work equip- ment. Move each piston more than once in order to deaerate the system; check again and top up if necessary. 14 -Put back the left cover (1) and the lower cover (2) and close the engine hood. 3 4 RWA10810 9 8 5 7 5 6 RWA10820 3 4 RWA10810 CAUTION • Do not start the engine with empty tank, since this would certainly damage the pump. 3 3 MAX. 10 MIN.
RWA10830 RWA06730