. MAINTENANCE SERVICE PROCEDURE MAINTENANCE SERVICE PROCEDURE 7. Open drain valve (7) and drain the water. bleed valve (8). radiator is full, start the 4 - 29 6. Remove covers (4) a nd (5) at the rear of the m achine, p drain hose (6), and p repare a container to catc h the wa REMARK When adding water to the cooling system, keep air bleed va open. This allows the a When the air is remove ir to escape during the f d and water comes out, illing ope close air 8. engine and run at low idling to raise the temperature to at least 90°C (194°F), then con 10 minutes. 9. Stop the engine and open drain valve (3), (7) t o drain th 10. Close drain valve (3), 11.
Add coolant until it ov erflows from the water fil ler. Decide the proportion s of antifreeze and water accordin g to the table for the mixing rate 12. To bleed the air from the cooling water, start th e engine , run for 5 minutes at low idling, minutes at high idling . (When doing this, leave the cool 13. Drain the coolant in side reserve tank, flus h the ins reserve tank , then ad marks. d coolant to between the FULL and 14. Stop the engine and tighten the cap. Check th e coolant and add water if the l