24. SERVICE PROCEDURE 24.6.5 CHANGE OIL IN HYDRAULIC TANK, REPLACE HYDRAULIC OIL FILTER ELEMENT The oil is at high temperature immediately after the machine ing the oil. When removing the oil filler cap, turn it slowly to Prepare the following. o Container to catch drained oil: Min. 58 e capacity l Refill capacity: 58 e (15.31 US gal, 12.76 UK gal) l Socket wrench, filter wrench 1. Lower the blade to the ground, stop the engine, move the blade control lever backwards and forward (left and right), then turn the cap of oil filler port @ slowly to release the pressure, and remove the cap. 2. Set a container under drain plug @ to catch the oil. 3.
Remove drain plug 0, then loosen drain valve 0, drain the oil, then tighten plug @ and valve @ again. When loosening drain valve 0, be careful not to get oil on yourself. AE112080 4. Remove bolt 0, then pull up cover 0, and remove element @ and the valve together with the cover. 5. Wash the inside of the case with clean diesel oil or flushing oil, then install a new element. 6. After replacing the element, add the specified amount of engine oil through oil filler 0. For details of the oil to use, see “20. USE OF FUEL, COOLANT AND LUBRICANTS ACCORDING TO AMBIENT TEMPERATURE”. 7. Check that the oil is at the specified level. For details, see “24.4 EVERY 250 HOURS SERVICE”. AE112110 3-54