John Deere 2120 Tractor — tm4252

70 Hydraulic System 30-10 Selective Control Valve (Poppet Type) Model 2120 Tractor TM-4252 (Dec-70) As the cam touches the return valve roller, the dial indicator should read 0.01 to 0.016 in. (= 0.25 to 0.40 mm). When the control lever or rocker is moved in the opposite direction, the cam moves against the pressure valve roller. Here the dial indicator should read 0.037 to 0.043 in. (0.94 to 1.1 mm). To decrease play, turn adjusting screw inwards, to increase turn outwards. Tighten lock nuts when valves are adjusted. 15. Reinstall valve springs, valve guides and cover. Do not remove valves unless necessary. Valves must be readjusted, if they are removed and reinstalled.

METERING VALVE ADJUSTMENT Install selective control valve assembly. 11. Check the "0" position on the dial indicator as explained in paragraphs 5 and 6. Connect hydraulic tester (as described in section 70, group 5) to selective control valve and check oil flow (see Specifications). 12. Back off special adjusting tool set screws from control lever side. Tighten set screws on opposite side to press return valve and pressure valve that have not yet been adjusted against the valve seats. Set dial indicator at zero. VALVE LEAKAGE CHECK Check valve leakage by connecting a hose, approx. 2 ft. (70 cm) long, with pressure gauge to quick coupler outlet.

With engine running, adjust pressure (operating selective control valve) to 1500 psi. (105 kg/cm2). 13. Adjust second return valve and pressure valve in the same manner as before. The adjusting dimensions are the same as above. If pressure valves are leaking, pressure will increase. If return valves are leaking, pressure will decrease. See Specifications for maximum permissible leakage. CAUTION: The pressure valves and return valves are arranged "crosswise" (see fig. 10). O.D. of pressure or return valves ..... . ...... 0.4960 to 0.4970 in. 12.600 to 12.624 mm 14. After having adjusted these valves, recheck "0" position of dial indicator and adjustment of all four valves.

Readjust, if necessary. O.D. of flow control valve ............ ... 0.7480 to 0.7490 in. 19.000 to 19.025 mm SPECIFICATIONS O.D. of metering valve . ................ 0.6235 to 0.6245 in. 15.837 to 15.862 mm O.D. of detent piston ....... . ......... 0.7450 to 0.7470 in. 18.923 to 18.974 mm Dimensions of new parts Spring of pressure valve Free length 1.812 in. 46 mm Resilience at a length of 1.25 in. (31.8 mm) ........ 36 to 44 lbs. 17 to 20 kg Spring of return valve Free length 1.562 in. 39.7 mm Resilience at a length of 1.25 in. (31.8 mm) ........ 19 to 23 lbs. 8.6 to 10.5 kg Printed in Germany