Operating principle Operating principle When one of the RCV lever (1) is set to the operation position, the each spool is shifted to left or right and the pilot oil flow is blocked. Then the pilot oil go to SH of the time delay valve (3). This pressure moves spool (5) to the leftward against the force of the spring(8), so pilot pump charged oil (P3) goes to the chamber G through port PG. This pressure is applied to move the piston (16) to the upward against the force of the spring (19). Thus, it releases the brake force. Θ a. 20 17 SH PG 1 1 RCV lever 2 Main control valve 3 Time delay valve 5 Spool 8 Spring 16 Brake piston 19 Brake spring P3 2 48092SM04 2-67 5 8 8