hyundai R510LC-7 — 4. POWER BOOST SYSTEM

GROUP 4 POWER BOOST SYSTEM 51075MS04 When the power boost switch on the left control lever knob is pushed ON, the maximum digging power is increased by 10 % . When the power set is at H or S and the power boost function is activated, the power boost solenoid valve pilot pressure raises the set pressure of the main relief valve to increase the digging power. Default - Power boolst solinoid valve : OFF 5-7 Description Power boost switch OFF ON ON Power set H or S H Main relief valve set press ure 330kgf/cm2 360kgf/cm2 Time of operation - Even when pressed continuously, it is canceled after 8 sec.